Mechanical Equipment Design
Plant Engineering: Storage Tanks

Specialized Storage Tank Design & Detail Engineering

From shop-fabricated vessels to complex field-erected tank farms. API 650, API 620 & ASME compliant.

We have partnered with global EPCs and fabricators to deliver fabrication-ready engineering packages. Our scope includes full mechanical design, shell/head development, and structural access integration, designed to eliminate site-level conflicts and shop-floor bottlenecks, under strict NDA protocols.

API 650 / API 620 / ASME OSHA / ASTM / CSA / EN PIP Standards
335+ storage tanks detailed, shop and field fabricated
Dual-material construction: stainless and carbon steel
Circular and rectangular, fixed roof to full agitator systems

End-to-end engineering support

Design calculations
General arrangement drawings
Fabrication & shop detailing
Shell plate development
Roof & bottom plate layouts
Nozzle orientation & detailing
Structural steel detailing
Material take-offs (MTO/BOM)
Complete fabrication documentation
335+
Tanks detailed
763,541
Max capacity (gal)
684 in.
Max tank ID

Across Global Sectors

Oil & gas

Upstream & downstream

Petrochemical

Refineries

Chemical processing

Process plants

Power

Generation & utilities

Water

Water & wastewater

Food & beverage

Storage & processing

Shop-fabricated & field-erected range

SHOP FABRICATED (160+)

1,181 to 47,554 gallons; 60 in. OD to 204 in. ID; 304-304L S/S, 316 - 316L S/S, carbon steel material

FIELD FABRICATED (175+)

93,296 to 763,541 gallons; 252 in. to 684 in. ID; 304-304L S/S, 316 - 316L S/S, carbon steel material

CONFIGURATIONS

Circular and rectangular tanks; fixed roof (dome, flat, cone) or ASME heads

Detailed engineering services we offer

We offer flexible engineering support tailored to your specific strategy.

Custom Shell Configurations

Dimple jackets, jumper arrangements, internal/external coils, and double-wall secondary containment for high-transfer surfaces.

Top & Bottom Head Diversity

Fixed roofs (dome, flat, cone) and pressure-rated ASME heads (ellipsoidal, torispherical, standard F&D).

Agitator-Ready Execution

Structural top-head reinforcement and calculated internal baffle arrangements for agitator assemblies.

Construction & Logistics

Jig and fixture design for field-welded alignment, plus transport shipping saddles for zero structural deformation in transit.

Wind, Seismic & Foundation Analysis

Wind and seismic load analysis, foundation load calculations, 3D modeling, and project-specific design optimization, for safe, economical, standards-compliant solutions.
API 650 API 620 ASME OSHA ASTM / CSA / EN AISC PIP
304-304L S/S, 316 - 316L S/S, carbon steel material

A complete, fabrication-ready package

Mechanical shell design, head and support calculations, and complete fabrication blueprints, including nozzle and detail interfaces mapped to PIP standards.

Plus structural access drawings: catwalks, platforms, handrails, ladders with safety cages, and spiral stairs for field-erected tanks.

Fabrication blueprints Foundation drawings BOM Access structures

Tank design to fabrication blueprints

Upstream/downstream tank farms, chemical storage, sanitary stainless steel storage

Two ways we deliver your tank

Shop-fabricated

Drafting packages sized for shop assembly
Custom transport shipping saddles, engineered for zero deformation in transit

Field-erected

Tank farm installations, jig & fixture design for weld alignment
Spiral stairs and intermediate access platforms for large-scale field tanks
Add tank design capacity without adding headcount
Engineers who work API 650 calculations daily
Full documentation handed off for your own client compliance
Quality checks built into every design stage
Trusted partner to top global EPC firms under strict NDA protocols

We design products for demanding customers

Quality assurance

Our team is dedicated to making sure all the design is up to your quality and expectations.

Decade of experience

Over 0+ products designed and delivered.

Intellectual property

Go through a strict onboarding process; we don't keep any intellectual property. Our design, your patent.

On-time deliveries

Our teams monitor the progress and provide daily updates to ensure that deliveries are always on time.
โ˜…โ˜…โ˜…โ˜…โ˜…
UK
"Acufore and their employees are very professional and show good knowledge. They are always keen to help us and resolve any issues / queries quickly and efficiently. When a timescale is given for a task it is generally always achieved. A great company to work with."
Project Manager
UK
โ˜…โ˜…โ˜…โ˜…โ˜…
US
"We enjoyed working with your team! Thank you for the support! We will work together again."
Director of Engineering
US
โ˜…โ˜…โ˜…โ˜…โ˜…
South Africa
"Acufore is a very professional company which we have done many projects with. The team is great to work with and always get the job done to a very high standard."
Project Coordinator
South Africa

Frequently asked questions

What information do you need to get started?

+
Storage capacity, the media being stored, and site conditions are enough to begin. Existing drawings help for brownfield or modification work, but aren't required up front.

Do you provide PE/P.Eng. stamped drawings?

+
We don't directly provide PE/P.Eng. stamped drawings. For regulated industries that require a stamp, we work alongside our customers or their local PE/P.Eng. partner to get drawings stamped. Our designs are completed to API 650 and API 620 for atmospheric storage tanks, with OSHA, ASTM, CSA, and EN standards for access structures, and PIP standards for piping interfaces.

What codes do you design to?

+
API 650 and API 620 for atmospheric storage tanks, with OSHA, ASTM, CSA, and EN standards for access structures, and PIP standards for piping interfaces.

How do you make sure a shop-built tank survives transport?

+
Custom transport shipping saddles are engineered as part of the design package, specifically to prevent structural deformation between the shop and the site.

Do I need to commit to a long-term contract?

+
No. Most clients start with a single tank or a single project to evaluate fit, then scale up only if it makes sense.

Ready to start? Fill out the form to your right, or call +1 (281) 491-1281.